Sabtu, 09 November 2013

NG160 - High performance circuit breakers up to 160 A


NG160 - High performance circuit breakers up to 160 A

-
  • Rated current: 16 to 160 A
  • 3 breaking performances: 16, 25 and 36 kA under 415 V
  • Rated operational voltage: 500 V AC
  • 3-and 4-pole version
  • NA type switch version
  • Fixed thermal trip unit
  • Earth leakage protection by associated Vigi module (upstream or downstream rigid connections)
  • Optional auxiliaries: position indication, tripping indication, shunt trip or undervoltage trip control, extended rotary control
  • Compliance with standards IEC 60947-1-2-3
Benefits
Ready to install
Benefiting from all the simplicity of modular installation, the NG160 circuit-breaker combines the performance and robustness essential for tertiary and industrial installations.
Applications
Protection in all tertiary and industrial buildings:

  • Incoming protection in modular enclosures
  • Outgoing protection in power switchboards

ID-RCCB - Multi 9 residual current circuit breakers up to 125A


ID-RCCB - Multi 9 residual current circuit breakers up to 125A

Residual current circuit breakers up to 125A
  • Nominal current: 1 to 125 A
  • 30mA sensitivity: additional protection against direct contact (in accordance with IEC 364)
  • 100, 300, 500 mA sensitivities: additional protection against fire and indirect contact (in accordance with IEC 364)
  • B type: protection of installations with three-phase rectifier
  • Type "si": protection of sensitive circuits (computing equipment) and those prone to disturbances (ballast lighting, power electronics)
  • Selective version : tripping of the device the closest to the fault
  • Compliance with standards: IEC EN 61008 certified by national official authorities
  • Suitable for isolation in accordance with industrial standards: IEC 60947
  • Operating voltage: up to 440Vac, insulation voltage: 500V
  • Optional auxiliaries: indication of state and tripping, shunt trip, undervoltage trip, overvoltage trip
Benefits
Quality without boundaries
The ID-RCCB residual current devices are simply natural complements to C60 and C120 circuit-breakers.
The "si" type ID-RCCBs are completely immune to disturbances, thus providing unequalled peace of mind.
Applications
Protection, in all industrial and tertiary buildings, against:
  • electrocution (in accordance with installation standards IEC 364 and national standards)
  • the risk of fire due to leakage currents into building materials