TeSys LR9 - Electronic thermal overload relays with build-in alarm function from 18,5 kW to 315 kW



TeSys LR9 - Electronic thermal overload relays with build-in alarm function from 18,5 kW to 315 kW

-
  • 8 ratings
2 versions:
  • Simplified version: class 10, class 20
  • Complete version: can be selected as class 10 or 20, with an alarm function enabling tripping to be anticipated by shedding the load
  • Settings locked by sealing the transparent flap
  • Connectors: screw clamp
Benefits
Electronics harnessed for motor starters
These ingenious electronic relays have a built-in alarm function, a wide adjustment range and a high level of accuracy suitable for the most demanding applications. They can be mounted directly below the LC1-D115/150 and LC1-E contactors to form extremely compact motor starters.
Applications
  • Industry, infrastructure, building, etc :
- Standard motor protection
- Line protection
- Protection: motor overload, stalling, loss of phase

TeSys LT47 - Electronic overcurrent relays 0,5 A to 60 A

-
  • DIN rail or plate mounting
  • Screw clamp or lug connections
  • External 24 to 230 V AC power supply
  • Manual or automatic reset depending on model.
  • Protection functions:
- Overcurrents due to overload or mechanical jamming: starting and steady state operation overtorque monitoring.
- Can be used as torque surge protection.
  • Current threshold adjustment using 2 separate time settings (starting and trip in steady state operation)
  • 2 LED indicators (starting and overtorque).
  • Auxiliary contacts: 1 N/C + 1 N/O
  • Looped cabling possible when the motor current is less than the minimum setting.
Benefits
Machine protection combined with motor starter
With its simple setting and signalling features, the electronic overcurrent relay, or overtorque protection relay, assures optimal protection of your machine.
Due to its compactness it easily integrates in the motor starter functions.
Applications
Industry, infrastructures, buildings:
  • Machines with high resistive torque.
  • High inertia machines.
  • Machines with high risk of jamming during steady state operation.
These relays do not have thermal memory and can be used as specific motor protection in the case of severe duty applications:
  • Machine with long starting time.
  • Machine with frequent starting.

TeSys LR97D - Electronic overcurrent relays 0,3 A to 38 A


TeSys LR97D - Electronic overcurrent relays 0,3 A to 38 A

-
  • Direct mounting beneath TeSys Model d contactors up to LC1D38, width 45 mm
  • Screw clamp or lug connections
  • External 24 to 230 V AC power supply
  • Manual or automatic reset
  • Protection functions:
    - Overcurrents due to overload or mechanical jamming: starting and steady state operation overtorque monitoring - Can be used as torque surge protection
    - Specific protection for locked rotor
    - Specific protection for phase failure.
  • Current threshold adjustment using 2 separate time settings (starting and trip in steady state operation)
  • Selection of 3-phase or single-phase operation
  • Diagnostics via 2 LED indicators (starting, overtorque, rotor locked and phase failure)
  • Auxiliary contact: 1 C/O.
Benefits
Machine protection combined with motor starter
With its simple setting and signalling features, the electronic overcurrent relay, or overtorque protection relay, assures optimal protection of your machine.
Due to its compactness  (45 mm wide) it easily integrates in the motor starter functions.
Applications
Industry, infrastructures, buildings:
  • Machines with high resistive torque
  • High inertia machines
  • Machines with high risk of jamming during steady state operation.
These relays do not have thermal memory and can be used as specific motor protection in the case of severe duty applications:
  • Machine with long starting time
  • Machine with frequent starting.

TeSys K - Contactors and reversing contactors up to 7.5kW 400/415V

are here: Home > Products > Contactors & Protection Relays > Contactors & Reversing Contactors > TeSys K

TeSys K - Contactors and reversing contactors up to 7.5kW 400/415V

-
  • Common options available for all ratings: 6, 9, 12 A
  • Control circuits available: AC, DC, low-consumption DC, silent
  • Applications: 2.2 kW, 4.5 kW, 5.5 kW in AC3 and AC4
  • Connectors: screw clamp, faston connectors, spring terminals, pins for printed circuit boards
Benefits
Compact performance
Tesys k forms a complete range of reversing or non-reversing contactors, offering the best performance/compactness ratio and seamless integration in all your applications.
Applications
  • Industry, infrastructure, building, etc :
- Simple control systems
- Zones sensitive to noise, disturbed mains supplies: silent contactor
- Use compatible with programmable controller outputs: low-consumption contactor

TeSys F - Contactors and reversing contactors up to 450 kW/400 V and 2100 A/AC1


TeSys F - Contactors and reversing contactors up to 450 kW/400 V and 2100 A/AC1

Contactors and reversing contactors up to 450 kW/400 V and 2100 A/AC1
Contactors and reversing contactors:
  • All AC and DC control voltages 50/400 Hz
  • "Power" connection
  • Screw connectors
  • Flexibility by addition of additives
  • Fast, simple mounting together with TeSys GV7-R circuit breaker for motor starter solution
  • Safety of operation.
  • TeSys F AC3 range:
    • For motor applications up to 450 kW / 400V
    • Control of all types of motors in normal or severe service conditions
  • TeSys F AC1 range:
    • For resistive applications up to 2100 A/AC1
    • For applications like:
      • Wind turbines
      • UPS panels
      • Frequency drives and soft starters
      • Light distribution circuits
      • Induction furnaces
      • Etc.
Benefits
The possibilities of a powerful offer
  • TeSys F offers very high performance in AC3 and AC1 applications.
  • Combined with the LR9 electronic relay or GV7 motor circuit breaker, AC3 contactors are the ideal motor starters, offering quick, simple selection as well as shared accessories for greater flexibility.
  • TeSys F also includes a dedicated AC1 offer.
  • TeSys F contactors guarantee electrical coordination with fuses and Masterpact NW circuit breaker offers
Applications
  • Industry, infrastructure, building, renewable energies, etc.
  • Control of all types of motors in normal or severe service conditions
  • Control of resistive, inductive and capacitive circuits.

TeSys D - Contactors and reversing contactors up to 75 kW/400 V and 250 A/AC1


TeSys D - Contactors and reversing contactors up to 75 kW/400 V and 250 A/AC1

Contactors and reversing contactors up to 75 kW/400V and 250A/AC1
» AC, DC, low-consumption DC control circuit
» All types of starter: reversing or non-reversing, star/delta, by auto-transformer, etc
» Connectors: spring terminal, EverLink terminal block, screw clamp, ring-type connection, Faston connector.
» Easy and simple direct mounting beetween contactor and circuit breaker, according to  EverLink terminal block (from 40 to 65 A).
Benefits
Take control of integration
In addition to its new look, the TeSys D contactor offers you quick simple setup, while maintaining a compact size of 45 and 55 mm (40 to 65 A) as well as compliance with international standards. From 40 to 65 A versions are equiped with EverLink, this new patented terminal technology, assures a permanent tightening quality even in the event of conductor creep.
Applications
Industry, infrastructure, building, etc:
  • TeSys D contactors have been designed for perfect integration in control systems
  • They can be used to create motor starters for any type of application.

TeSys B - Bar contactors up to 900 kW


TeSys B - Bar contactors up to 900 kW

-
4 sizes:
  • LC1-BL up to 800 A/AC-1
  • LC1-BM up to 1250 A/AC-1
  • LC1-BP up to 2000 A/AC-1
  • LC1-BR up to 2750 A/AC-1
4 arrangements of instantaneous contacts. Combinable thermal overload relays: LR9-F, LT6
Benefits
Quick, simple selection.
Applications
  • Industry, infrastructure, building, etc.:
- Control of all types of motor in normal or severe service conditions
- Control of resistive, inductive and capacitive circuits.