Model |
PX3 |
PX2 |
PX7 |
PX9 |
Appearance |
|
|
|
|
W 횞 H 횞 D (mm) |
96 횞 48 횞 100 |
48 횞 96 횞 100 |
72 횞 72 횞 100 |
96 횞 96 횞 100 |
Function |
�냽Input filter: OFF,
---1 ~ 120 sec. |
�냽External contact input |
�냽Heating/Cooling control |
�냽Fuzzy
�냽Auto tuning |
�냽Retransmission output
---(PV, SV, MV) |
�냽Ramp & Soak |
�냽Interface (RS 485 / 422) |
�냽Zone PID
�냽3 Alarm outputs |
�냽Heating/Cooling
---hysteresis |
�냽Output limitation |
�냽Protection : IP 65 (Front) |
�냽Group PID
�냽Universal-input/outputs |
|
Input |
Thermocouple : K, J, E,
T, R, S, B, L, N, U, WRe 5-26, PL - �뀫 |
R.T.D : Pt 100 �꽗, KPt 100 �꽗 |
Direct voltage : 1 - 5 V, -10 ~ 20 mV, 0 ~ 100 mV (Free scale type) |
|
Sampling
cycle |
250mS, ( Remote option
: 500mS ) |
Input
display resolution |
Below decimal point of
input signal and Measuring range |
Input
impedance |
T.C and mV input : Min,
1 �뢾 d.c V : 1 �뢾 |
Source
tolerable
resistance |
Thermocouple : Max. 250 �꽗, Voltage : Max. 2 �? |
Lead
wire tolerable
resistance |
R.T.D : Max. 10 �꽗 /wire (notice : Identical conductor resistance between 3 wires) |
Input
tolerable voltage |
± 10 V (T.C, R.T.D, Voltage
: mV d.c), ± 20 V (Voltage : V d.c) |
Noise
removal rate |
NMRR (Normal mode) :
40dB min. CMRR(Common mode) : 120 dB min.(50/60 �럯 ± 1 %) |
Standard |
T/C, R.T.D : KS, IEC, DIN |
Scaling |
According to setting max.
value(SH), min. value (SL) of measuring range,
scaling is available
(-1999 ~ 9999) |
Standard
junction temp.
compensation tolerance |
± 1.5 �숦(15 ~ 35 �숦), ± 2.0 �숦(0 ~ 50 �숦) |
Burn-out |
T.C : OFF, Up/Down selectable
R.T.D : OFF, UP selectable
( Detection current : 50 mA) |
Accuracy |
±0.1% (Full scale) |
Power
supply for sensor |
24 V d.c (Internal resistance : 1.2 �?) Max. 50 mA |
15 V d.c (Internal resistance : 600 |
|
Model |
Code |
Information |
PX |
- |
|
|
Multi input/output temperature controller |
Dimension |
2 |
|
|
48(W) 횞 96(H) mm |
3 |
|
|
96(W) 횞 48(H) mm |
7 |
|
|
72(W) 횞 72(H) mm |
9 |
|
|
96(W) 횞 96(H) mm |
Control Type |
0 |
|
Universal type (possible to select either ther reverse operation direct operation) |
1 |
|
Heating/cooling control (synchronous control output) |
Option |
0 |
NONE |
1 |
PX7 : RS485/422M OUT2, REM(Remote input function) |
PX9 : RS485/422, HBA 2 Contact, REM |
|
2 |
RS485/422, OUT2, HBA 1 Contact |
3 |
Contact input (D,I), OUT2, HBA 1 Contact |
Cautions) 1) PX2 and PX3 cannot be applied with any option choices. |
---------------2) PX9 can be applied with only option number 1. |
---------------3) PX7 can be applied with all of the option choices. |
|
|
|